<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005">
<channel xmlns:cfi="http://www.microsoft.com/schemas/rss/core/2005/internal" cfi:lastdownloaderror="None">
<title cf:type="text"><![CDATA[Editorial Board of Journal of Pharmaceutical Research -->Column on Genotoxic Impurities Research]]></title>
<item>
<title xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="text"><![CDATA[Determination of potential genotoxic impurity in Enalaoril Hydrochlorothiazide preparation by UHPLC-MS/MS method]]></title>
<link><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202308008&flag=1]]></link>
<description xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="html"><![CDATA[<b>Objective</b>  To establish an UHPLC-MS/MS method for the determination of N-nitroso hydrochlorothiazide in enalapril hydrochlorothiazide preparations by synthesizing the genotoxic impurity N-nitroso hydrochlorothiazide (NO-HZCT). <b>Methods</b>  NO - HZCT was synthesized by reference method, its molecular weight and structure were confirmed by high resolution mass spectrometry; The separation was performed on an Agilent Eclipse Plus C<sub>18</sub> RRHD (3.0 mm×150 mm, 1.8 μm) column with the mobile phase consisting of 10 mmol·L<sup>-1</sup> ammonium formate- 0.1% formic acid aqueous solution(mobile phase A) and 0.1% formic acid solution (mobile phase B) by gradient elution at a flow rate 0.6 mL•min<sup>-1</sup>; Multiple reaction monitoring (MRM) was performed on a triple quadruple mass spectrometer with a ESI source in positive mode to quantitative detection of NO-HZCT. <b>Results</b>   The calibration curve was linear for NO-HZCT in the range 0.51~50.67 ng•mL<sup>-1</sup>,Coefficient of correlation（<i>r</i>）was 0.999 7; The recoveries (<i>n</i>=3) of low, middle and high  adding concentrations were 93.10% (<i>RSD</i> 3.7%), 104.30% (RSD 1.0%) and 106.48% (<i>RSD</i> 1.8%), respectively; The LOD and LOQ were 0.08 ng•mL<sup>-1</sup> and 0.027 ng•mL<sup>-1</sup>, respectively. NO-HZCT was detected in three batches of samples. <b>Conclusion</b>   The method is highly sensitive, accurate, and can accurately detect the genotoxic impurity NO - HZCT in enalapril hydrochlorothiazide preparations, which can provide a reference for the quality control of enalapril hydrochlorothiazide preparations and ensure the drug safety.]]></description>
<pubDate>2023/9/11 16:16:02</pubDate>
<category><![CDATA[Column on Genotoxic Impurities Research]]></category>
<author><![CDATA[YUAN Song, ZHANG Caiyu, YU Liju, CHEN Hua, ZHANG Qingsheng]]></author>
<atom:author xmlns:atom="http://www.w3.org/2005/Atom">
<atom:name>YUAN Song, ZHANG Caiyu, YU Liju, CHEN Hua, ZHANG Qingsheng</atom:name>
</atom:author>
<guid><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202308008&flag=1]]></guid><cfi:id>5</cfi:id><cfi:read>true</cfi:read></item>
<item>
<title xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="text"><![CDATA[Determination of genotoxic impurities impurities in Tenofovir disoproxil prodrug by LC-MS/MS]]></title>
<link><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202308009&flag=1]]></link>
<description xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="html"><![CDATA[<b>Objective</b>  To determine the content of genotoxic impurity 9-Propenyladenine in the prodrug of tenofovir dipivoxil by high performance liquid chromatography triple quadrupole mass spectrometry (LC-MS/MS). Analyze the impact of different curve fitting methods on the accuracy of the results. <b>Methods</b>  Using Waters XBridge C<sub>18</sub> column(4.6 mm×150 mm，3.5 μm); eluted by methanol-water (55:45) as the mobile phase, with flow rate of 1.0 mL·min<sup>-1</sup>. Injection volume 2 μL, column temperature of 40 ℃. Electrospray ionization source was used positive ion mode and multiple reaction monitoring(MRM) mode was performed with transitions of m/z 176.0→136.0.<b>Results</b>  The results have been validated by analytical methods, and the specificity of this method is good; System precision test <i>RSD</i>=1.1% (<i>n</i>=6); Linear regression with least square method, linear range 0.051~25.250 μg·mL<sup>-1</sup>； The accuracy of weighted linear regression in low concentration areas is significantly higher than that of unweighted linear regression. Quantitative limit concentration 0.051 ng·mL<sup>-1</sup>, detection limit concentration 0.017 ng·mL<sup>-1</sup>; The average recovery rate of the raw material drug sample solution is 99.08%~99.97% (<i>n</i>=9), and the repeatability <i>RSD</i> is 0.4%~1.3%; The average recovery rate of the tablet sample solution is 98.94%~101.96% (<i>n</i>=9), and the repeatability <i>RSD</i> is 0.2%~0.3%; good tolerance. <b>Conclusion</b>  The established method is characterized by simple operation, high sensitivity, fast analysis speed, and the matrix does not affect the detection. The results are accurate and reliable, and can meet the detection requirements for trace genotoxic impurities.]]></description>
<pubDate>2023/9/11 16:16:02</pubDate>
<category><![CDATA[Column on Genotoxic Impurities Research]]></category>
<author><![CDATA[ZHANG Lianyi, GUO Changchuan, WEN Songsong, CHEN Zhen, LI Lin, XU Yuwen]]></author>
<atom:author xmlns:atom="http://www.w3.org/2005/Atom">
<atom:name>ZHANG Lianyi, GUO Changchuan, WEN Songsong, CHEN Zhen, LI Lin, XU Yuwen</atom:name>
</atom:author>
<guid><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202308009&flag=1]]></guid><cfi:id>4</cfi:id><cfi:read>true</cfi:read></item>
<item>
<title xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="text"><![CDATA[Determination of genotoxic impurity N-nitroso-propranolol in propranolol hydrochloride sustained-release tablets by UHPLC-MS/MS]]></title>
<link><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202307009&flag=1]]></link>
<description xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="html"><![CDATA[<b>Objective</b>  To establish an UHPLC-MS/MS method for determination of N-nitroso-propranolol in propranolol hydrochloride sustained-release tablets. <b>Methods</b>  The separation of N-nitroso-propranolol was performed on a Waters ACQUITY UPLC®CSHTMC18 column (150 mm×3.0 mm, 1.7 μm) with 10 mmol·L<sup>-1</sup> ammonium formate aqueous solution (containing 0.1% formic acid) as mobile phase A and acetonitrile solution (containing 0.1% formic acid) as mobile phase B under a gradient elution at a flow rate of 0.5 mL·min<sup>-1</sup> and a column temperature of 50 ℃. Multiple reaction monitoring (MRM) was performed on a triple quadrupole mass spectrometer in positive mode.<b>Results</b> The calibration curves was in good linearity in the range of 1~20 ng·mL<sup>-1</sup>. The recoveries (<i>n</i>=3) at low, middle and high spiked concentrations were within 98.4%~103.2% with <i>RSD</i> under 2.7 %. The limit of detection was 0.09 ng·mL<sup>-1</sup>, and the limit of quantification was 0.3 ng·mL<sup>-1</sup>. Using the developed method, we detected the N-nitroso-propranolol in propranolol hydrochloride extended-release tablets was 1.8 μg·g<sup>-1</sup>.<b>Conclusion</b>  The method is sensitive and accurate, which can be applied for the quantifications of N-nitroso-propranolol in propranolol hydrochloride extended-release tablets, providing reference for quality control of propranolol hydrochloride sustained release tablets.]]></description>
<pubDate>2023/8/14 11:14:18</pubDate>
<category><![CDATA[Column on Genotoxic Impurities Research]]></category>
<author><![CDATA[HUANG Haiwei, YUAN Song, ZHANG Na, ZHANG Longhao, LIU Yang, ZHANG Qingsheng]]></author>
<atom:author xmlns:atom="http://www.w3.org/2005/Atom">
<atom:name>HUANG Haiwei, YUAN Song, ZHANG Na, ZHANG Longhao, LIU Yang, ZHANG Qingsheng</atom:name>
</atom:author>
<guid><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202307009&flag=1]]></guid><cfi:id>3</cfi:id><cfi:read>true</cfi:read></item>
<item>
<title xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="text"><![CDATA[Development and validation of an UHPLC–MS/MS method for ultra trace-level determination of two potential genotoxic impurities within regorafenib active pharmaceutical ingredient]]></title>
<link><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202307010&flag=1]]></link>
<description xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="html"><![CDATA[<b>Objective</b>  To establish an LC-MS/MS analytical method for the determination of genotoxic impurities in regorafenib. <b>Methods</b>  The method was achieved on a Agilent RRHD C<sub>18</sub> column (2.1 mm×100 mm, 1.8 μm) utilizing a mobile phase of 0.05% Formic acid water(A)- Methanol（B）with gradient elution at the flow rate of 0.3 mL·min<sup>-1</sup>. The temperature of column was set at 35 ℃. The AGILENT 1290-6470A LC-MS was used to detect (AJS ESI source, in Multiple Reaction Monitoring mode). <b>Results</b>  The specificity, linearity and range, LOQ and LOD, accuracy, precision and stability of the method were all in accordance with the validation of Chinese Pharmacopoeia. <b>Conclusion</b> The proposed method was successfully applied to determine the trace-level PGIs in two batches of regorafenib. The contents of SM2 were not observed in the two batches of samples, whereas the contents of SM3 were determined to be 13.6×10<sup>-6</sup> and 41.4×10<sup>-6</sup>, respectively.]]></description>
<pubDate>2023/8/14 11:14:18</pubDate>
<category><![CDATA[Column on Genotoxic Impurities Research]]></category>
<author><![CDATA[CHEN Shuang, LIU Zhu, SHI Yunfeng, ZHU Jia, LUO Ying]]></author>
<atom:author xmlns:atom="http://www.w3.org/2005/Atom">
<atom:name>CHEN Shuang, LIU Zhu, SHI Yunfeng, ZHU Jia, LUO Ying</atom:name>
</atom:author>
<guid><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202307010&flag=1]]></guid><cfi:id>2</cfi:id><cfi:read>true</cfi:read></item>
<item>
<title xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="text"><![CDATA[UPLC-MS/MS法测定磷酸西格列汀中基因毒性杂质NTTP]]></title>
<link><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202312009&flag=1]]></link>
<description xmlns:cf="http://www.microsoft.com/schemas/rss/core/2005" cf:type="html"><![CDATA[]]></description>
<pubDate>2024/1/10 16:01:45</pubDate>
<category><![CDATA[Column on Genotoxic Impurities Research]]></category>
<author><![CDATA[袁松，李婕，张娜，张龙浩，刘阳，张庆生]]></author>
<atom:author xmlns:atom="http://www.w3.org/2005/Atom">
<atom:name>袁松，李婕，张娜，张龙浩，刘阳，张庆生</atom:name>
</atom:author>
<guid><![CDATA[http://www.yaoxueyanjiu.org.cn/ch/reader/view_abstract.aspx?file_no=202312009&flag=1]]></guid><cfi:id>1</cfi:id><cfi:read>true</cfi:read></item>
</channel>
</rss>