| 摘要: |
| 目的 通过优化CCK-8的实验条件,提高检测药物影响肿瘤细胞增殖的敏感性和可靠性。方法 以人肺癌A549细胞和白血病Molt-4细胞为研究对象,CCK-8法和MTT法分别检测细胞增殖的变化,并与Coulter细胞计数法和克隆形成率法进行比较。结果 在相同的细胞数下,CCK-8法的检测灵敏度明显高于MTT法。以细胞密度1 000个/孔接种,抗肿瘤药物多柔比星处理96 h后,CCK-8法检测到的变化与克隆形成率法相当。分析Molt-4悬浮细胞发现:CCK-8法与Coulter细胞计数法的检测灵敏度无明显差异(P>0.05)。结论 优化实验条件后,CCK-8法是一种灵敏度高、可靠性良好的细胞增殖检测方法 |
| 关键词: CCK-8法 细胞增殖 药效 多柔比星 |
| DOI:10.13506/j.cnki.jpr.2016.02.001 |
| 基金项目:国家自然科学基金课题(No.81273553);北京协和医学院2015年研究生创新基金(No.2015-1007-18) |
|
|
|
| Optimization study on the detection of tumor cell proliferation with CCK-8 method |
| ZHANG Huiqun,HE Qiyang |
| (Institute of Medicinal Biotechnology,Chinese Academy of Medical Sciences and Peking Union Medical College,Beijing 100050,China) |
| Abstract: |
| Objective To optimize the experiment condition and increase the reliability and sensibility of CCK-8 method in detecting the proliferation of tumor cells by drugs.Methods The proliferations of A549 and Molt-4 cells were detected by CCK-8 and MTT method,respectively. Meanwhile the sensitivity and accuracy were compared to cloning formation assay and Coulter cytometer.Results The sensitivity of CCK-8 assay was significantly higher than that of MTT assay at the same cell density.The reliability of CCK-8 was equivalent to the efficiency of clone formation assay when the cell density was seeded at 1 000 per well and treated with doxorubicin for 96 h.There were no significant differences in sensitivity and reliability of CCK-8 and Coulter cytometer assay on suspension cells(P>0.05).Conclusion CCK-8 is a kind of good assay for cell viability with a higher sensitivity and reliability during improved experiment conditions. |
| Key words: CCK-8 assay Cell proliferation Drug efficacy Doxorubicin |