引用本文:闵春艳,唐杰,吴杨,鲁辉,邢以文.气相色谱法测定鹿血酒中的甲醇和杂醇油[J].药学研究,2017,36(8):446-449,456[点击复制]
【打印本页】      【下载PDF全文】   【查看/发表评论】  【下载PDF阅读器】  【关闭】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 3520次   下载 3157次 本文二维码信息
码上扫一扫!
气相色谱法测定鹿血酒中的甲醇和杂醇油
闵春艳1,2,唐杰3,吴杨1,鲁辉1,邢以文1
字体:加大+|默认|缩小-
(1.苏州市药品检验检测研究中心,江苏 苏州 215104;2.苏州大学,江苏 苏州 215123;3.南京中医药大学,江苏 南京 210023)
摘要:
目的 建立气相法测定鹿血酒中甲醇和仲丁醇、正丙醇、正丁醇、异丁醇、异戊醇5种杂醇油成分。方法 Agilent HP-INNOWax(30 m×320 μm×0.25 μm)柱;程序升温;进样口温度230 ℃,进样量1 μL,分流比50:1;氢火焰离子化检测器(FID),温度250 ℃;外标法定量。结果 鹿血酒中甲醇与5种杂醇油成分分离良好,在一定浓度范围内线性关系良好;加样回收率为91.6%~106.3%,定量限为2~11 μg·mL-1,检出限为1~6 μg·mL-1。结论 本法简便,准确,可用于鹿血酒中甲醇和5种杂醇油成分的含量测定。
关键词:  鹿血酒  甲醇  杂醇油  气相色谱法  外标法
DOI:10.13506/j.cnki.jpr.2017.08.004
基金项目:
Determination of methanol and fusel oils in Luxue Wine by gas chromatography
MIN Chunyan1,2,TANG Jie3,WU Yang1,LU Hui1,XING Yiwen1
(1.Suzhou Institute for Drug control, Suzhou 215104, China; 2.Soochew University, Suzhou 215123,China; 3.Nanjing University of Chinese Medicine, Nanjing 210023,China)
Abstract:
Objective To establish a method for the determination of methanol and fusel oils including 2-butyl alcohol,n-propanol,isobutanol,n-butanol and isoamyl alcohol in Luxue Wine by gas chromatography.Methods An Agilent HP-INNOWax (30 m×320 μm×0.25 μm) column was applied to analyze methanol and five fusel oils in Luxue Wine by GC method with the programmed temperature procedure.The temperature of injector was 230 ℃, the injection volume was 1 μL and the split ratio was 50:1.Flame ionization detector (FID) was applied and the temperature was 250 ℃.The external standard method was used to quantify the content of methanol,2-butyl alcohol,n-propanol,isobutanol,n-butanol and isoamyl alcohol in Luxue Wine. Results The components of methanol,2-butyl alcohol,n-propanol,isobutanol,n-butanol and isoamyl alcohol in Luxue Wine were well separated.The components showed a good linear relationship in a certain concentration range.The average recovery was in the range of 91.6%~106.3%.The limit of quantitation (LOQ) was in the range of 2~11 μg·mL-1;The limit of detection(LOD) was in the range of 1~6 μg·mL-1.Conclusion The method was simple and accurate for the determination of methanol,2-butyl alcohol,n-propanol,isobutanol,n-butanol and isoamyl alcohol in Luxue Wine.
Key words:  Luxue Wine  Methanol  Fusel oil  Gas Chromatography  External standard method