| 摘要: |
| 目的 建立同时测定盐酸西替利嗪和5种防腐剂含量的方法。方法 采用高效液相色谱法,色谱柱为Inertsil ODS-3(4.6 mm×250 mm,5 μm),流动相为乙腈:0.1%冰醋酸(40:60,V/V),流速为1.5 mL•min-1,检测波长为238 nm,柱温为30 ℃,进样量为20 μL。结果 盐酸西替利嗪和5种防腐剂的浓度与峰面积呈良好的线性关系(r≥0.999 7);其精密度、稳定性试验的RSD<2.0%;平均加样回收率分别为99.9%、99.8%、99.8%、99.7%、99.5%、100.2%,RSD分别为0.5%、0.5%、0.4%、0.5%、1.1%、1.2%。结论 本方法简便、高效、准确、重复性好,可用于盐酸西替利嗪和不同防腐剂的含量测定和质量控制。 |
| 关键词: 高效液相色谱法 盐酸西替利嗪 防腐剂 含量测定 |
| DOI:10.13506/j.cnki.jpr.2018.03.007 |
| 基金项目: |
|
|
|
| Simultaneous determination of cetirizine hydrochloride and 5 preservatives by HPLC |
| LU Qichun |
| (Jiangsu Ascendia Pharmaceutical Co., Ltd.,Nantong 226200,China) |
| Abstract: |
| Objective To establish a method for the simultaneous determination of cetirizine hydrochloride and 5 preservatives.Methods The HPLC,column was Inertsil ODS-3 (4.6 mm×250 mm,5 μm),the mobile phase was acetonitrile:0.1% acetic acid (40:60, V/V),the flow rate was 1.5 mL•min-1,the detection wavelength was 238 nm,the column temperature was 30 ℃,the injection volume was 20 μL.Results The concentration showed a good linear relationship with the peak area of cetirizine hydrochloride and 5 preservatives (r≥0.9997);The RSD of the precision and stability test was less than 2.0%; The average recovery was 99.9%、99.8%、99.8%、99.7%、99.5%、100.2%, and RSD,respectively, 0.5%, 0.5%, 0.4%, 0.5%, 1.1%, 1.2%.Conclusion This method is simple,efficient,accurate and reproducible.It can be used for the determination and quality control of cetirizine hydrochloride and different preservatives. |
| Key words: HPLC Cetirizine hydrochloride Preservatives Determination |