| 摘要: |
| 目的 建立超高效液相色谱-串联三重四级杆质谱联用测定药品包装材料中双酚A的检测方法。方法 采用BEH C18液相柱分离,流动相为乙腈和水,采用梯度洗脱方式,电喷雾离子源,负离子扫描,多反应监测模式进行质谱分析。结果 BPA在0.5~106.3 ng·mL-1范围内,线性关系良好(r=0.9 999)。结论 该方法操作简便,灵敏度高,能满足药品包装材料中双酚A含量的测定。 |
| 关键词: 双酚A 超高效液相色谱-串联质谱法 药包材 |
| DOI:10.13506/j.cnki.jpr.2019.04.006 |
| 基金项目: |
|
|
|
| Determination of bisphenol A in pharmaceutical packaging by ultra high performance liquid chromatography-mass spectrometry |
| ZHAI Meijuan,CHEN Bowen,TANG Lian |
| (Pharmacy Department, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou 215002,China) |
| Abstract: |
| Objective To establish a method for the determination of bisphenol A in pharmaceutical packaging materials by ultrahigh performance liquid chromatography -tandem triple quadruple mass spectrometry.Methods BEH C18 column was used to separate acetonitrile and water as mobile phase. Gradient elution method, electrospray ion source,negative ion scanning and multi-reaction monitoring mode were used for mass spectrometry analysis.Results The linear calibration curve of bisphenol A was obtained in the concentration range of 0.5~106.3 ng·mL-1 (r=0.999 9).Conclusion The method was simple, sensitive and can be used to determine the content of bisphenol A in pharmaceutical packaging materials. |
| Key words: Bisphenol A Ultra-high performance liquid Chromatography-tandem Mass Spectrometry Pharmaceutical packaging materials |