| 摘要: |
| 目的 建立了气相色谱法准确测定左卡尼汀原料药中三甲胺的检测方法。方法 采用程序升温法,FID检测器,色谱柱为Pora PLOT Amines毛细管柱(25 m×0.32 mm×10 μm)进行测定。结果 在选定的测定条件下,三甲胺在0.081 6~4.079 7 μg﹒mL-1范围内与峰面积呈良好的线性关系,相关系数为0.999 1,平均回收率为99.6%(RSD=1.9%),检测限为0.025 0 μg﹒mL-1。结论 该气相色谱方法准确,灵敏度高,可用于左卡尼汀原料药中三甲胺的质量控制。 |
| 关键词: 左卡尼汀 三甲胺 气相色谱法 |
| DOI:10.13506/j.cnki.jpr.2020.12.005 |
| 基金项目: |
|
出版日期:2020-12-25
|
|
| Determination of trimethylamine in levocarnitine raw material by headspace capillary gas chromatography |
| SONG Wenji,LIU Yin,HU Changqing,WANG Dongyue,WU Ning |
| (Shandong Qidu Pharmaceutical Co.,Ltd.,Shandong Provincial Key Laboratory of Neuroprotective Drugs,Zibo 255400,China) |
| Abstract: |
| Objective A gas chromatography method was established for the accurate and sensitive determination of trimethylamine in levocarnitine raw material.Methods A Pora PLOT Amines capillary column and flame ionization detector were used with temperature programing.Results Under the selected condition, the concentration of trimethylamine in the range of 0.081 6 ~4.079 7 μg﹒mL-1 showed a good linear relationship with the peak area with a correlation coefficient of 0.999 1, the average recovery was 99.6%(RSD=1.9%) and the limit of detection was 0.025 0 μg﹒mL-1.Conclusion The method is of high accuracy and sensitivity and can be used to supervise the trimethylamine in levocarnitine raw material. |