| 摘要: |
| 目的 建立电感耦合等离子体质谱(ICP-MS)同时测定人凝血因子Ⅷ/血管性血友病因子复合物冻干注射剂中硼(B)、镁(Mg)、铝(Al)、硅(Si)、钒(V)、镉(Cr)、锰(Mn)、铁(Fe)、钴(Co)、镍(Ni)、铜(Cu)、锌(Zn)、锶(Sr)、锆(Zr)、钼(Mo)、铑(Rh)、钯(Pd)、锡(Sn)、钡(Ba)、铈(Ce)、铅(Pb)元素含量的方法。方法 样品经微波消解后,以钪(Sc)、锗(Ge)、铟(In)、铋(Bi)为内标,采用电感耦合等离子体质谱(ICP-MS)法同时测定上述元素的含量。ICP-MS 功率为1550 W,采样深度为10.0 mm,等离子气、雾化气、辅助气流量分别为15.0、0.99、0.9 L·min-1,泵速为0.10 r·s-1,雾化室温度为2℃,硼(B)元素采用No Gas调谐模式,其它元素采用He调谐模式,数据采集3次。结果 21种元素在测定的浓度范围内,线性关系良好,相关系数r>0.9990;检出限为0.001~2.04 µg·L-1;各元素回收率为87.78%~102.72%,RSD为1.31%~7.91%。结论 该方法快速简便、灵敏度高、准确性好,可用于人凝血因子Ⅷ/血管性血友病因子复合物冻干注射剂中金属元素的检测。 |
| 关键词: 金属元素 微波消解 人凝血因子Ⅷ/血管性血友病因子复合物冻干注射剂 电感耦合等离子体质谱 |
| DOI:10.13506/j.cnki.jpr.2021.10.005 |
| 基金项目: |
|
出版日期:2021-10-25
|
|
| Determination of 21 Elements in Human Coagulation Factor Ⅷ/von Willebrand Factor Complex Lyophilized Injection by ICP-MS |
| JIANG Shuyin,ZHANG Xunjie,ZHANG Naibin,LI Chunhuan,HE Meilian,SHI Feng,XIAN Ruiqing |
| (Shandong Institute for Food and Drug Control, Shandong Research Center of Engineer and Technology for Consistency Evaluation of Generic Drugs,National Medical Products Administration(NMPA) Key laboratory for Quality Evaluation of Gelatin Products, Jinan 250101, China) |
| Abstract: |
| Objective To establish an inductively coupled plasma mass spectrometry (ICP-MS) method for the simultaneous determination of boron (B), magnesium (Mg), aluminum (Al), silicon (Si), vanadium (V), cadmium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), copper (Cu), zinc (Zn), strontium (Sr), zirconium (Zr), molybdenum (Mo), rhodium (Rh), palladium (Pd), tin (Sn), barium (Ba), cerium (Ce) and lead (Pb) in human coagulation factor VIII/von Willebrand factor complex lyophilized injection. Methods After microwave digestion of samples, with scandium(Sc), germanium(Ge), indium(In) and bismuth(Bi) as internal standard, the content of the above elements were determined by inductively coupled plasma mass spectrometry(ICP-MS) method at the same time, the ICP-MS power was 1550 W, sampling depth was 10.0 mm, plasma gas, carrier gas and auxiliary gas flow were 15.0, 0.99, 0.9 L·min-1 respectively, the pump speed was 0.10 r·s-1, the atomizing chamber temperature was 2 ℃, reaction mode was No Gas(B) and helium (others), data was collected for three times.Results The 21 elements have a good linear relationship within the measured concentration range, the correlation coefficient r was > 0.999; the detection limit was 0.001~2.04 µg·L-1; the recoveries of each element were 87.78%~102.72%, and the RSDs were 1.31%~7.91%. Conclusion The method was rapid, simple, sensitive and accurate, and can be used for the detection of metal elements in freeze-dried injections of human coagulation factor VIII/von Willebrand factor complex. |
| Key words: Metal elements Microwave digestion Human Coagulation Factor Ⅷ/von Willebrand factor complex lyophilized injection Inductively coupled plasma mass spectrometry |