| 摘要: |
| 目的 建立高效液相色谱法测定药用卤化丁基橡胶塞中2-巯基苯并噻唑含量的方法。方法 使用丙酮作为萃取剂,对药用卤化丁基橡胶塞中的2-巯基苯并噻唑进行微波萃取。采用ZORBAX SB-C8(4.6mm×250mm,5 μm)色谱柱,流动相为1%乙腈水溶液和乙腈,梯度洗脱,流速1.0 mL·min-1,检测波长320 nm,柱温为25 ℃,进样量10 μL。结果 2-巯基苯并噻唑在1.02~102.26 μg·mL-1的浓度范围内线性良好(r=0.999 9),检出限达到0.03 µg·mL-1,精密度、稳定性RSD均小于3%,样品加标回收率为97.8%~108.9%。2种药用卤化丁基橡胶塞中均未检测到2-巯基苯并噻唑。结论 经方法学验证,本法可用于药用卤化丁基橡胶塞中2-巯基苯并噻唑含量的测定。 |
| 关键词: 药用卤化丁基橡胶塞 高效液相色谱法 2-巯基苯并噻唑 含量测定 |
| DOI:10.13506/j.cnki.jpr.2022.09.004 |
| 基金项目: |
|
出版日期:2022-09-25
|
|
| Determination of 2-mercaptobenzothiazole in pharmaceutical halogenated butyl rubber stopper |
| JIA Feifei,CHENG Jiamei,ZHAO Xia,YANG Huiying,XIAO Xinyue |
| (National Institutes for Food and Drug Control, Beijing 100050, China) |
| Abstract: |
| Objective To establish a HPLC method for the determination of 2-mercaptobenzothiazole (2-MBT) in the pharmaceutical halogenated butyl rubber stopper.Methods 2-MBT was extracted from pharmaceutical halogenated butyl rubber stopper with acetone by microwave. The separation was performed on a ZORBAX SB-C8 (4.6 mm×250 mm, 5 μm) column with mobile phase consisted of 1% acetonitrile aqueous solution and acetonitrile by gradient elution at the flow rate of 1.0 mL·min-1. The detection wavelength was 320 nm, column temperature was 25 ℃, and injection volume was 10 μL. Results The linear relationships of 2-MBT was good in the concentration range of 1.02 ~ 102.26 μg·mL-1 (r=0.999 9), the detection limit was 0.03 µg·mL-1, RSDs of precision and stability were less than 3%, and the recovery rates were 97.8%~108.9%. No 2-MBT was detected in 2 kinds of halogenated butyl rubber stopper. Conclusion The method can be used for the determination of 2-MBT in pharmaceutical halogenated butyl rubber stopper. |
| Key words: Halogenated butyl rubber stopper HPLC 2-mercaptobenzothiazole Determination |