| 摘要: |
| 目的 建立电阻法测定病毒样颗粒粒径的方法。方法 采用库尔特纳米粒度仪对人乳头瘤病毒(Human papilloma virus,HPV)疫苗原液的粒径进行测定。从准确性、精密度和重复性进行方法学验证同时与负染电镜结果比较。结果 100 nm标准微球平均粒径为102.00±0.00 nm,测定6次结果为102.33 ± 0.52 nm。样品测定6次,结果为78.67 ± 1.37 nm。表明该方法具有较好的准确性、精密度和重复性。样品测量结果与负染电镜结果相当。样品56 ℃放置30 分钟,大颗粒最多。结论 电阻法可用于病毒样颗粒产品的粒径检测、粒度分布和稳定性监测。 |
| 关键词: 库尔特电阻法 人乳头瘤病毒 粒径与粒径分布 病毒样颗粒 |
| DOI:10.13506/j.cnki.jpr.2025.02.004 |
| 基金项目:国家重点研发计划项目(No.2021YFC2302505) |
|
出版日期:2025-02-25
|
|
| Determination of particle size of virus-like particle of HIV by resistance pulse sensor method |
| LU Qiong1,NA Tao2,HUANG Weijin1,NIE Jianhui1 |
| (1.Division of HIV/AIDS and Sex-transmitted Virus Vaccines,Institute for Biological Product Control,National Institutes for Food and Drug Control,State Key Laboratory of Drug Regulatory Science,NHC Key Laboratory of Research on Quality and Standardization of Biotech Products,NMPA Key Laboratory for Quality Research and Evaluation of Biological Products,Beijing 102629,China;2. The Cell Collection and Research Center, National Institutes for Food and Drug Control,Beijing 102629,China) |
| Abstract: |
| Objective To establish a method for determining the particle size of virus like particles using the Resistance Pulse Sensor (RPS) method. Methods The NanoCoulter Resun G03 was used to measure the particle size of the human papillomavirus (HPV) vaccine stock solution. Methodological validation was conducted on accuracy, precision, distinguishability, and repeatability, and the particle size detection results were compared with dynamic light scattering and negative staining electron microscopy results. Results The average particle size of 100 nm standard microspheres was 102.00 ± 0.00 nm, and the result of 6 measurements was 102.33 ± 0.52 nm. The sample was measured 6 times and the result was 78.67 ± 1.37 nm. This indicates that the method has good accuracy, precision, and repeatability. The sample measurement results are comparable to the negative staining electron microscopy results. The sample was left at 56 ℃ for 30 minutes, with the highest number of large particles.Conclusion The resistance method can be used for particle size detection and stability monitoring of virus like particle products. |
| Key words: Coulter resistance method Particle size and particle size distribution Virus like particles |