| 摘要: |
| 目的 建立多糖铁复合物中铁的含量测定方法。方法 采用紫外-可见分光光度法,在酸性条件下加热使Fe3+游离后,用盐酸羟胺还原成Fe2+,再与邻菲罗啉反应形成红色络合物,以紫外-可见分光光度法在(510±2)nm波长处测定其含量。结果 本方法线性关系良好(r=0.999 9),平均回收率为100.51%(RSD=0.64%)。结论 本方法操作简便准确,重复性好,可用于多糖铁复合物的铁含量测定。 |
| 关键词: 紫外-可见分光光度法 多糖铁复合物 含量 |
| DOI:10.13506/j.cnki.jpr.2015.11.009 |
| 基金项目: |
|
|
|
| Determination of iron content in Iron Polysaccharide Complex by UV-VIS |
| ZHAN Xiaolin,TIAN Hongwei,WANG Jing |
| (Shanghai Pharmaceutical Group Qingdao Growful Pharmaceutical Co.,Ltd.,Qingdao 266000,China) |
| Abstract: |
| Objective To establish a method for the determination of iron content in Iron Polysaccharide Complex.Methods Under the acid condition,Fe3+ was dissociated from Hongyuanda Capsules by heating ,then Fe3+ was deoxidized into Fe2+ by hydroxylamine hydrochloride, and red Fe2+ -orthophenanthroline complex was formed through combination with o-phenanthroline. The content was determined by UV-VIS at a wavelength of (510±2 )nm.Results The linearity was good(r=0.999 9),the average recovery was 100.51%(RSD=0.64%).Conclusion The method was simple,reliable and reproducible,and can be used for the determination of iron content in Iron Polysaccharide Complex. |
| Key words: Ul-VIS Iron Polysaccharide Complex Content |