LI Xingchun,LU Jie,LI Jie,LI Lailing.Determination of antioxidant 1010,antioxidant 330,antioxidant 1076 and antioxidant 168 in high density polyethylene barrels for blood dialysis concentrate packing by HPLC[J].Journal Of Pharmaceutical Research,2016,35(2):86-88[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 10661times   Download 4381次 QR Code for this article
Scan with your phone!
HPLC法测定高密度聚乙烯桶包装血液透析浓缩液中抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168的含量
李兴春,路杰,李洁,李来玲
Font:Larger+|Default|Smaller-
(青岛普瑞森医药科技有限公司,山东 青岛 266111)
摘要:
目的 建立高密度聚乙烯桶包装血液透析浓缩液中抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168的含量测定方法。方法 采用岛津Inertsil ODS-3色谱柱(4.6 mm×250 mm,5 μm),流动相∶乙腈-水(93∶7),流速1.0 mL·min-1,柱温30 ℃,检测波长为276 nm。结果 抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168分别在2.53~30.36、2.56~30.72、2.54~30.45、2.56~30.66 μg·mL-1范围内线性关系良好,相关系数r均大于0.999。抗氧剂1010、抗氧剂330、抗氧剂1076、抗氧剂168的平均回收率(n=9)分别为92.72%、91.40%、90.68%、90.37%,RSD均小于5.0%。结论 该方法专属性强、精密度和检测灵敏度高,重复性好,含量测定准确度好,可用于高密度聚乙烯桶包装血液透析浓缩液中抗氧剂的质量控制。
关键词:  高效液相色谱  高密度聚乙烯桶  血液透析浓缩液  抗氧剂
DOI:10.13506/j.cnki.jpr.2016.02.008
基金项目:
Determination of antioxidant 1010,antioxidant 330,antioxidant 1076 and antioxidant 168 in high density polyethylene barrels for blood dialysis concentrate packing by HPLC
LI Xingchun,LU Jie,LI Jie,LI Lailing
(Qingdao Precision Medical Tech Co.,Ltd.,Qingdao 266111,China)
Abstract:
Objective To establish a determination method of antioxidant 1010,antioxidant 330,antioxidant 1076 and antioxidant 168 in high density polyethylene barrels for hemodialysis concentrate packing.Methods Shimadzu Inertsil ODS-3 column (4.6 mm×250 mm, 5 µm) was used with acetonitrile-water (93:7) as flow phase.The flow rate was 1.0 mL•min-1,the column temperature was 30 ℃ and the detection wavelength was 276 nm.Results Antioxidant 1010, antioxidant 330, antioxidant 1076 and antioxidant 168 showed good linear relationship in range of 2.53~30.36,2.56~30.72,2.54~30.45,2.56~30.66 µg•mL-1,respectively.The correlation coefficient r was above 0.999.The average recovery (n=9) of antioxidant 1010,antioxidant 330,antioxidant 1076 and antioxidant 168 were 92.72%, 91.40%,90.68%,90.37%,respectively,and the RSD was less than 5.0%.Conclusion The method had good specificity, high sensitivity and precision, and its repeatability and accuracy of determining the content was good.It can be used to control the quality of antioxidants in high density polyethylene barrels for hemodialysis concentrate packaging.
Key words:  HPLC  High density polyethylene barrels  Hemodialysis concentrate  Antioxidant
Today's Visits:438    Total Visits:2383115
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.