Cite this article:
ZHANG Xinjun,LIANG Ruixue,ZHOU Shenghong,YAN Xuesheng,LI Ying.Determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in Jingjie Kanggan Mixture by HPLC[J].Journal Of Pharmaceutical Research,2016,35(4):209-211[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3472times   Download 3422次 QR Code for this article
Scan with your phone!
HPLC测定荆桔抗感合剂中盐酸麻黄碱和盐酸伪麻黄碱的含量
张新军,梁瑞雪,周胜红,闫雪生,李莹
Font:Larger+|Default|Smaller-
(山东省中医药研究院,山东 济南 250014)
摘要:
目的 建立用反相高效液相色谱法测定荆桔抗感合剂中盐酸麻黄碱和和盐酸伪麻黄碱含量的方法。方法 采用C18柱,流动相为乙腈-0.2%磷酸溶液(5:95),流速为1.0 mL•min-1,紫外检测波长为210 nm。结果 盐酸麻黄碱线性浓度范围0.079 5~2.385 μg,相关系数r=0.999 9,平均回收率99.4%,相对标准偏差RSD为0.47%(n=6)。盐酸伪麻黄碱线性浓度范围0.078 75~2.362 5 μg,相关系数r=0.999 9,平均回收率100.7%,相对标准偏差RSD为1.09%(n=6)。结论 本法重复性好,定量准确,可作为该制剂的定量分析方法。
关键词:  盐酸麻黄碱  盐酸伪麻黄碱  荆桔抗感合剂  高效液相色谱
DOI:10.13506/j.cnki.jpr.2016.04.006
基金项目:山东省中医药科技发展计划项目(No.2013Z002-2)
Determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in Jingjie Kanggan Mixture by HPLC
ZHANG Xinjun,LIANG Ruixue,ZHOU Shenghong,YAN Xuesheng,LI Ying
(Shandong Institute of Traditional Chinese Medicine,Jinan 250014,China)
Abstract:
Objective To establish a method for the determination of ephedrine hydrochloride and pseudoephedrine hydrochloride in Jingjie Kanggan Mixtrue by HPLC.Methods The C18 column with acetonitrile-0.2%H3PO4(5:95) as the mobile phase was used.The flow rate was 1.0 mL•min-1 and the detective wavelength was 210 nm.Results The linear range of ephedrine hydrochloride was 0.079 5~2.385 μg (r=0.999 9).The average recovery was 99.4% and RSD was 0.47%(n=6).The linear range of pseudoephedrine hydrochloride was 0.078 75~2.362 5 μg(r=0.999 9).The average recovery was 100.7% and RSD was 1.09%(n=6).Conclusion This method was accurate with a good repeatability and can be used as a quantitative analysis for this preparation.
Key words:  Ephedrine hydrochloride  Pseudoephedrine hydrochloride  Jingjie Kanggan Mixture  HPLC
Today's Visits:527    Total Visits:2383269
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com