ZHANG Xiaoli,LING Yiping,LUO Yaqin,XU Shaojing.Study on dissolution of Mitiglinide Calcium Gydrate Tablets[J].Journal Of Pharmaceutical Research,2016,35(6):347-350[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3192times   Download 2897次 QR Code for this article
Scan with your phone!
米格列奈钙片的溶出度研究
张晓丽,凌益平,骆雅琴,徐绍静
Font:Larger+|Default|Smaller-
(正大青春宝药业有限公司,浙江 杭州 310023)
摘要:
目的 建立米格列奈钙片剂溶出度的测定方法,比较自制样品与原研品在四种溶出介质中溶出曲线。方法 以水900 mL为溶剂,桨法,转速为75 rpm,溶出度的测定采用高效液相色谱法。结果 米格列奈钙在2.775~33.300 μg•mL-1范围内,线性关系良好(r=0.999 9),平均回收率为99.38%,自制样品与原研品在4种溶出介质中溶出行为都很相似。结论 建立的米格列奈钙片剂溶出度测定方法简便、准确、可靠,可较好地控制该片剂质量,自制样品与原研品体外溶出行为很接近。
关键词:  米格列奈钙  片剂  溶出度  高效液相色谱法  溶出曲线
DOI:10.13506/j.cnki.jpr.2016.06.013
基金项目:
Study on dissolution of Mitiglinide Calcium Gydrate Tablets
ZHANG Xiaoli,LING Yiping,LUO Yaqin,XU Shaojing
(Chiatai Qingchunbao Pharmaceutical Co.,Ltd.,Hangzhou 310023,China)
Abstract:
Objective To establish a dissolution determination method of Mitiglinide Calcium Hydrate Tablets and compare the self-made sample with the original preparation by stripping curves in four different dissolution media.Methods The dissolution was determined with paddle method (75 rpm) in 900 mL water and detected by high performance liquid chromatography (HPLC).Results There was a good linearity over the range of 2.775~33.300 μg•mL-1 with a correlation coefficient r=0.999 9,and average recovery was 99.38%.Dissolution behaviors of self-made sample and original preparation were similar in four different dissolution media.Conclusion The method was simple,accurate,reliable and the quality of Mitiglinide Calcium Hydrate Tablets can be well controlled by this method.The dissolution behaviors of two samples were very similar in vitro.
Key words:  Mitiglinide calcium hydrate  Tablets  Dissolution  High performance liquid chromatography  Stripping curve
Today's Visits:488    Total Visits:2383203
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.