盐酸莫西沙星氯化钠注射液有关物质检查方法研究
张锡霞,李永贵,王晶
Font:Larger+|Default|Smaller-
(山东省药学科学院,山东省化学药物重点实验室,山东 济南 250101)
摘要:
目的 建立盐酸莫西沙星氯化钠注射液有关物质检查的方法。方法 采用苯基柱(4.6 mm×150 mm,5 μm),流动相为乙腈-盐溶液(30:70),检测波长为293 nm,流速为1.3 mL·min-1,柱温为30 ℃。结果 莫西沙星与各已知杂质及降解产物均分离良好,系统适用性良好,杂质A、B、C、D、E线性良好。杂质B、杂质E校正因子分别为1.4、3.5。结论 本方法检查盐酸莫西沙星氯化钠注射液有关物质专属性强、灵敏度高、准确可靠、重现性好。
关键词:  莫西沙星  有关物质  校正因子
DOI:10.13506/j.cnki.jpr.2016.09.010
基金项目:
Study on Related Substances in Moxifloxacin Hydrochloride and Sodium Chloride Injection
ZHANG Xixia,LI Yonggui,WANG Jing
(Shandong Academy of Pharmaceutical Sciences,Shandong Provincial Key Laboratory of Chemical Drug,Jinan 250101,China)
Abstract:
Objective To establish a method for the inspection of related substances in Moxifloxacin Hydrochloride and Sodium Chloride Injection.Methods The determination was carried on a phenysilyl column(4.6 mm×150 mm,5 μm)with acetonitrile-saline solution(30:70) as mobile phase.The detection wavelength was 293 nm.The flow rate was 1.3 mL·min-1,and the column temperature was 30 ℃.Results The developed method could be used for the determination of moxifloxacin,known impurities and its degradation products with a good resolution,the system suitability was fine.The impurities(A,B,C,D,E) had good linearity.The corresponding correction factor:impurities B=1.4,impurities E=3.5.Conclusion The method can be special,sensitive and accurate with good reproducibility for the inspection of related substances in Moxifloxacin Hydrochloride and Sodium Chloride Injection.
Key words:  Moxifloxacin  Related substances  Correction factor
Today's Visits:487    Total Visits:2383201
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.