| 摘要: |
| 目的 对全国不同地区市售全蝎中氯化钠的含量进行测定。方法 收集了30个省份的138批次全蝎样品。采用建立的振荡提取和滴定法测定全蝎中氯化钠的含量。结果 应用所建立的方法对样品进行定量分析,结果氯化钠溶液浓度在0.204 8~6.404 6 mg·mL-1范围之间呈良好的线性关系。氯化钠的平均加样回收率为100.4%,RSD为0.78%。138批次样品中氯化钠含量在2.55%~39.86%之间。结论 所建立的氯化钠测定方法操作简便,重现性好,结果准确可靠,可用于全蝎中氯化钠含量的快速检测。市售全蝎中氯化钠含量差异较大,存在超量掺盐问题,有必要加强全蝎的市场监管,以保证临床用药的安全性。 |
| 关键词: 全蝎 氯化钠 含量测定 |
| DOI:10.13506/j.cnki.jpr.2017.07.004 |
| 基金项目: |
|
Publication Date:July 25, 2017
|
|
| Determination of sodium chloride in commercial Scorpio from different areas |
| WANG Bing,XIE Yingying,ZHOU Qianqian,LIN Yongqiang |
| (Shandong Institute for Food and Drug Control,Jinan 250101,China) |
| Abstract: |
| Objective To determine the content of sodium chloride in commercial Scorpio from different areas.Methods The 138 batch of commercial Scorpio were collected from 30 areas.The vibrating extraction and titrimetric analysis were adapted to assay sodium chloride in Scorpio.Results Samples were determined by the new method.There was a good linear relationship between the absorption titration volume and the concentration in the range of 0.204 8~6.404 7 mg·mL-1 for sodium chloride.The average recovery of standard addition were 100.4%, RSD were 0.78% (n=6).The determination method of sodium chloride were between 2.55% and 39.86%.Conclusion The method can be very fast to determine sodium chloride in Scorpio,with easy operation,reproducible and accurate feasibility.Scorpio on markets were big difference in the content of sodium chloride,It was necessary to strengthen the market monitoring of Scorpio to ensure the safety and effectiveness of Scorpio in clinic. |
| Key words: Scorpio Sodium chloride Assaying |