| 摘要: |
| 目的 建立复方碳酸钙泡腾颗粒中维生素D3含量检测方法。方法 采用Phenomenex Luna 3μ Silica(2) 100A色谱柱(4.6 mm×100 mm,3 μm),以正己烷-正戊醇(997:3)为流动相,检测波长254 nm,柱温30 ℃,流速1.5 mL·min-1,进样量200 μL。结果 维生素D3在浓度0.6215~1.1654 μg·mL-1范围内线性关系良好(r=0.999 5),平均回收率为100.7%(RSD=1.80%,n=9)。结论 所用方法简便、准确、专属性强、重复性好,能够检测复方碳酸钙泡腾颗粒中维生素D3含量。 |
| 关键词: 复方碳酸钙泡腾颗粒 维生素D3 |
| DOI:10.13506/j.cnki.jpr.2017.07.007 |
| 基金项目: |
|
Publication Date:July 25, 2017
|
|
| Method improvement of determination of vitamin D3 in Compound Calcium Carbonate Effervescent Granules |
| MA Li,WANG Yingxin,WANG Longjiang,TAO Yuanjing |
| (Shandong Dyne Marine Biopharmaceutical Co.,Ltd.,Rongcheng 264300,China) |
| Abstract: |
| Objective To establish a method for the determination of vitamin D3 in Compound Calcium Carbonate Effervescent Granules.Methods The separation was performed on Phenomenex Luna 3μ Silica(2) 100A column(4.6 mm×100 mm,3 μm).The mobile phase was n-hexane and n-amyl alcohol (997:3).The detection wavelength was 254 nm and the column temperature was 30 ℃.The injection volume was 200 μL.Results The liner range was 0.6215~1.1654 μg·mL-1(r=0.999 5).The recovery of method was 100.7%(RSD=1.80%,n=9).Conclusion The method was simple,accurate and sensitive for the determination of vitamin D3 in Compound Calcium Carbonate Effervescent Granules. |