Cite this article:
ZOU Wenbo,WANG Yan,YIN Lihui,HU Changqin.Particlesize distribution analysis of cilomilast using laser diffraction method[J].Journal Of Pharmaceutical Research,2018,37(2):93-95[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3400times   Download 3111次 QR Code for this article
Scan with your phone!
应用激光散射法测定西洛司特粒度分布
邹文博,王琰,尹利辉,胡昌勤
Font:Larger+|Default|Smaller-
(中国食品药品检定研究院,北京 102629)
摘要:
目的 用激光散射法测定西洛司特粒度分布,考察不同试验条件对结果的影响。方法 取西洛司特150 mg,用0.1%吐温-20溶液20 mL预分散后以水为分散剂测定,泵速2 100 rpm,颗粒折射率1.52,颗粒吸收率0.1,分散剂折射率1.33,背景/样品测量时间12秒。结果 3批样品的测定结果,d(0.1)、d(0.5)和d(0.9)分别为16.552、16.235 、16.417 μm;38.775、38.426、38.302 μm;71.455、71.487、71.279 μm。结论 本试验方法可用于测定西洛司特粒度分布,结果重现性好。
关键词:  激光散射法  西洛司特  粒度分布
DOI:10.13506/j.cnki.jpr.2018.02.008
基金项目:
Particlesize distribution analysis of cilomilast using laser diffraction method
ZOU Wenbo,WANG Yan,YIN Lihui,HU Changqin
(National Institutes for Food and Drug Control,Beijing 102629,China)
Abstract:
Objective To analyze the particle size distribution of cilomilast using laser diffraction method,and investigate the effect of different experimental conditions on the results.Methods 150 mg cilomilast was weighed,and added 20 mL 0.1% Tween-20 solution to disperse and take water as dispersant.The pump speed was 2 100 rpm.The particle refractive index and absorption index was 1.52 and 0.1,respectively.The dispersant refractive index was 1.33.Measurement time of background and sample was 12 seconds.Results The d(0.1),d(0.5) and d(0.9) of three batches of sample was 16.552,16.235,16.417 μm;38.775,38.426,38.302 μm;71.455,71.487,71.279 μm.Conclusion The method presented can be used to measure the particle size distribution of cilomilast with acceptable repeatability.
Key words:  Laser diffraction  Cilomilast  Particle size distribution
Today's Visits:468    Total Visits:2383167
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.