WANG Ruijuan,XIONG Yerong,TU Jiasheng.Study on the determination of platinum content of cisplatin in rat plasma[J].Journal Of Pharmaceutical Research,2018,37(6):315-317,331[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 4016times   Download 3885次 QR Code for this article
Scan with your phone!
顺铂在大鼠体内血药浓度测定方法学研究
王瑞娟,熊晔蓉,涂家生
Font:Larger+|Default|Smaller-
(中国药科大学,江苏 南京 210009)
摘要:
目的 建立大鼠血浆中铂含量测定的方法学,探讨顺铂经静脉注射给药后在大鼠体内的药动学过程。方法 采用浓硝酸消解法,石墨炉原子吸收法GFAAS测定血浆中铂含量。结果 第一步干燥温度100 ℃,时间20 s,第二步干燥温度150 ℃,时间30 s;灰化温度1 500 ℃,时间30 s,升温速率150 ℃·s-1;原子化温度为2 700 ℃,净化温度2 800 ℃下,此法测定铂标准曲线方程为:A=0.002 49C+0.007 2,相关系数为R2=0.999 7;检出限为1.93 ng·mL-1。结论 石墨炉原子吸收法测定血浆中铂含量的方法准确可靠,简便易行。
关键词:  顺铂  石墨炉  原子吸收
DOI:10.13506/j.cnki.jpr.2018.06.002
基金项目:国家自然科学基金项目(No.81673364);中央高校基本科研业务费专项资金资助(No.2632018YX02)
Study on the determination of platinum content of cisplatin in rat plasma
WANG Ruijuan,XIONG Yerong,TU Jiasheng
(China Pharmaceutical University,Nanjing 210009,China)
Abstract:
Objective To establish a method of platinum content determination in rat plasma.Methods Determination of platinum content in plasma by GFAAS with nitric acid digesting under the optimized conditions.Results The optimal heating program was as follows: The first step of drying at 100 ℃ for 20 s and the second step of drying at 150 ℃ for 30 s, ashing at 1 500 ℃ for 30 s, atomic transition at 2 700 ℃ and cleaning at 2 800 ℃, the standard curve equation for the determination of Pt content by this method was obtained: A=0.002 49C+0.007 2, the correlation coefficient for R2=0.999 7;the minimum detection limit was 1.93 ng·mL-1.Conclusion The determination of platinum content in plasma by graphite furnace atomic absorption was reliable and simple.
Key words:  Cisplatin  Graphite furnace  Atomic absorption
Today's Visits:483    Total Visits:2383194
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.