Cite this article:
LIN Tonghui,CHEN Juan,WANG Dongwu,SUN Lining,LIU Qian.Determination of relative substances in reduced glutathione by HPLC[J].Journal Of Pharmaceutical Research,2018,37(9):506-510[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3428times   Download 3731次 QR Code for this article
Scan with your phone!
HPLC法测定还原型谷胱甘肽原料药有关物质
林彤慧,陈娟,王东武,孙丽宁,刘茜
Font:Larger+|Default|Smaller-
(山东绿叶制药有限公司质量控制部, 山东 烟台 264003)
摘要:
目的  建立一种测定还原型谷胱甘肽中有关物质的反相高效液相色谱法。方法  色谱柱:Agilent Zorbax SB-Aq;以磷酸盐缓冲溶液-甲醇体系为流动相;流速为1.0 mL·min-1;柱温为30 ℃;检测波长为210 nm。结果  该方法精密度试验RSD≤5.0%;谷胱甘肽及杂质A、B、C、D在线性范围内线性相关系数 r≥0.999 7,检出限分别为0.002 9、0.003 4、0.003 1、0.005 5、0.004 1 μg,定量限分别为0.005 8、0.006 7、0.006 1、0.011、0.0081 μg;加标回收率分别为100.9%、99.4%、98.2%、103.2%。结论  该方法准确、灵敏,适用于谷胱甘肽中有关物质的检测。
关键词:  谷胱甘肽  有关物质  高效液相色谱法  杂质
DOI:10.13506/j.cnki.jpr.2018.09.004
基金项目:
Determination of relative substances in reduced glutathione by HPLC
LIN Tonghui,CHEN Juan,WANG Dongwu,SUN Lining,LIU Qian
(Quality Control Department,Shandong Luye Pharmaceutical Co.,Ltd.,Yantai 264003,China)
Abstract:
Objective  To establish a reversed phase high-performance liquid chromatography for the determination of relative substance in reduced glutathione.Methods  HPLC analysis was carried out with Agilent Zorbax SB-Aq.The mobile phase was phosphate buffer solution-method with a gradient elution program.The detection wavelength was 210 nm.The flow rate was 1.0 mL·min-1.The column temperature was 30 ℃.Results  The repeatability of RSD≤5.0%;The calibration curves of glutathione,impurity A,impurity B,impurity C and impurity D showed good linearities with the correction coefficients more than 0.999 7.The limits of detection (LOD) were 0.002 9 μg for glutathione,0.003 4 μg for impurity A,0.003 1 μg for impurity B,0.005 5 μg for impurity C and 0.004 1 μg for impurity D and the limits of qualification were 0.005 8 μg for glutathione,0.006 7 μg for impurity A,0.006 1 μg for impurity B,0.011 μg for impurity C and 0.008 1 μg for impurity D. The accuracies were good with the average recoveries of 100.9% for impurity A, 99.4% for impurity B, 98.2% for impurity C and 103.2% for impurity D.Conclusion  The method was accurate,sensitive,and suitable to measure the relative substance in reduced glutathione.
Key words:  Glutathione  Relative substance  HPLC  Impurities
Today's Visits:511    Total Visits:2383242
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com