• Home
  • About Journal
    Journal Introduction
    Editorial Board
    Youth Editorial Board
    Cooperating Institutions
    Editorial Department
  • Submission Guidelines
  • Policies & Statements
    Ethical Guidelines for Publication
    Academic Misconduct Statement
    Open Access (OA) Statement
    AIGC Use Statement
  • Journal Subscription
  • Download Center
  • 中文版
Cite this article:
AN Rui,DING Dazhong.Construction and verification of models for rapid determination of Nifedipine Sustained-release Tablets (II) by NIR[J].Journal Of Pharmaceutical Research,2018,37(9):513-515,519[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3438times   Download 3166次 QR Code for this article
Scan with your phone!
硝苯地平缓释片(II)近红外快速检验模型的建立与验证
安睿1,丁大中2
Font:Larger+|Default|Smaller-
(1.山东省青岛第二中学,山东 青岛 266061;2.青岛市食品药品检验研究院,山东 青岛 266071)
摘要:
目的 建立硝苯地平缓释片(II)近红外一致性检验模型和快速定量模型。方法 使用近红外漫反射光谱(NIR)技术并采用化学计量学方法,选择9 000~7 500 cm-1、6 900~5 600 cm-1和5 000~4 250 cm-1的谱段和二阶导数+矢量归一化的预处理方法建立一致性检验模型;选择7500~9750 cm-1的谱段和直线差减法建立一致性检验模型。结果 对收集的6批样品建立一致性检验模型并通过了模型验证;以3批原始样品及6批模拟样品作为校正集建立定量模型经交叉验证,硝苯地平的浓度范围为0.018 60~0.091 09 mg·mg-1,均方根误差(RMSECV)为0.001 95,确定系数(R2)为0.992 9;再以3批原始样品作为验证集进行外部验证,预测均方根误差(RMSEP)为0.000 531;预测结果与法定方法测得含量结果对比,偏差在1.5%之内。结论 所建模型准确、高效,厂家可用于在线质量监控、快速定量分析,监管部门可用于筛查、打击假劣药品。
关键词:  近红外漫反射光谱  硝苯地平缓释片(II)  快速检验模型
DOI:10.13506/j.cnki.jpr.2018.09.006
基金项目:
Construction and verification of models for rapid determination of Nifedipine Sustained-release Tablets (II) by NIR
AN Rui1,DING Dazhong2
(1.Qingdao No.2 Middle School of Shandong Province, Qingdao 266061,China; 2.Qingdao Institute for Food and Drug Control, Qingdao 266071,China)
Abstract:
Objective To establish a model for the rapid determination of Nifedipine Sustained- release Tablets (II).Methods Using methods of near infrared diffuse reflectance spectroscopy (NIR) and stoichiometry, the second derivative and vector normalization were selected as the preprocessing methods and 9 000~7 500 cm-1 ,6 900~5 600 cm-1,5 000~4 250 cm-1 were selected as the frequency range to establish conformity test model.The straight line subtraction was selected as the preprocessing methods and 7500~9750 cm-1 ,6900~5600 cm-1, 5000~4 250 cm-1 were selected as the frequency range to establish quantitative model.Results The conformity test model passed the model testing.The quantitative model was constructed based on 3 batches of commercial samples and 6 batches of laboratory samples and the sample’s contents were ranging from 0.01860 mg·mg-1 to 0.091 09 mg·mg-1.The root mean square errors of cross validation (RMSECV), determination coefficients (R2) and root mean square errors of prediction (RMSEP) were 0.001 95,0.992 9,0.000 531,respectively.The model was tested based on 3 batches of commercial samples and the results were well met with the legal methods with difference≤1.5%.Conclusion This method was accurate and efficient.It can be used for determination and quality control of Nifedipine Sustained- release Tablets(II).
Key words:  Near infrared diffuse reflectance spectroscopy  Nifedipine Sustained-release Tablets (II)  Rapid Testing model
Today's Visits:511    Total Visits:2383242
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.