• Home
  • About Journal
    Journal Introduction
    Editorial Board
    Youth Editorial Board
    Cooperating Institutions
    Editorial Department
  • Submission Guidelines
  • Policies & Statements
    Ethical Guidelines for Publication
    Academic Misconduct Statement
    Open Access (OA) Statement
    AIGC Use Statement
  • Journal Subscription
  • Download Center
  • 中文版
Cite this article:
DUAN Mengru,HE Dongsheng,SUN Huimin,XIONG Yerong,TU Jiasheng.Determination of Epoxide Impurity in Poloxamer 188 by Gas Chromatography[J].Journal Of Pharmaceutical Research,2020,39(6):331-335,340[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 3325times   Download 3735次 QR Code for this article
Scan with your phone!
气相色谱法检测泊洛沙姆188中环氧化物杂质
段梦茹1,何东升1,孙会敏2,熊晔蓉1,涂家生1
Font:Larger+|Default|Smaller-
(1.中国药科大学药学院,药用辅料及仿创药物研发评价中心,江苏 南京 210009;2.中国食品药品检定研究院,国家药品监督管理局药用辅料质量研究与评价重点实验室,北京 100050)
摘要:
目的 利用气相色谱法建立泊洛沙姆188中环氧乙烷、环氧丙烷及1,4-二氧六环的含量检查方法。方法 以超纯水作为溶剂,采用顶空气相色谱法检测泊洛沙姆188中环氧乙烷、环氧丙烷及1,4-二氧六环含量。结果 该方法的系统适用性、专属性、线性、精密度和准确度均符合规定,9批泊洛沙姆样品中均未检出环氧乙烷,环氧丙烷及1,4-二氧六环。结论 该方法简便、准确、可靠,可用于泊洛沙姆188中环氧乙烷、环氧丙烷及1,4-二氧六环含量检测。
关键词:  泊洛沙姆188  顶空气相色谱法  环氧化物  环氧丙烷  1,4-二氧六环
DOI:10.13506/j.cnki.jpr.2020.06.005
基金项目:国家科技重大专项-重大新药创制(No.2017ZX09101001-006-002);国家药典委员会-药品医疗器械审评审批制度改革专项课题(No.ZG2017-5-03)
Determination of Epoxide Impurity in Poloxamer 188 by Gas Chromatography
DUAN Mengru1,HE Dongsheng1,SUN Huimin2,XIONG Yerong1,TU Jiasheng1
(1.Center for Research Development and Evaluation of Pharmaceutical Excipients and Generic Drugs, School of Pharmacy, China Pharmaceutical University, Nanjing 210009,China;2.NMPA Key Laboratory for Quality Research and Evaluation of Pharmaceutical Excipients,National Institutes for Food and Drug Control,Beijing 100050,China)
Abstract:
Objective To establish the method for the determination of ethylene oxide, propylene oxide and 1,4-dioxane in poloxamer188 by gas chromatography.Methods Using ultrapure water as solvent, the content of ethylene oxide, propylene oxide and 1,4-dioxane in poloxamer188 was determined by headspace gas chromatography.Results The gas chromatography validation results for system suitability,specificity,linearity,precision,recovery,all met the requirement. Ethylene oxide, propylene oxide and 1,4-dioxane were not detected in the 9 batches of poloxamer samples.Conclusion The method is simple, accurate and reliable, and can be used for the detection of ethylene oxide, propylene oxide and 1,4-dioxane in poloxamer188.
Key words:  Poloxamer188  Headspace gas chromatography  Ethylene oxide  Propylene oxide  1,4-dioxane
Today's Visits:511    Total Visits:2383242
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.