Cite this article:
KONG Lingfeng,WANG Huan,LI Chengsen,GUO Hanwen,SUN Lingling.Analysis of metal elements in Guzhecuoshang Capsules by ICP-MS[J].Journal Of Pharmaceutical Research,2020,39(7):388-389,397[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 2656times   Download 2414次 QR Code for this article
Scan with your phone!
ICP-MS同时测定骨折挫伤胶囊中重金属的含量
孔令锋1,王欢2,李成森1,郭汉文1,孙苓苓1
Font:Larger+|Default|Smaller-
(1.辽宁省药品检验检测院,辽宁 沈阳 110036;2.山东泓润健康科技有限公司,山东 济南 250022)
摘要:
目的 建立测定骨折挫伤胶囊中铅(Pb)、镉(Cd)、铜(Cu)、砷(As)、汞(Hg)元素含量的电感耦合等离子体-质谱(ICP-MS)法。方法 样品经人工胃液提取,以锗(Ge)、铟(In)、铋(Bi)为内标,采用ICP-MS法同时测定5种元素。结果 5种元素质量浓度在线性范围内与响应强度线性关系良好,平均回收率97.4%~102.7%,RSD均小于3.5%(n=6)。结论 该方法准确,灵敏,无干扰,可用于骨折挫伤胶囊中5种重金属及有害元素的测定。
关键词:  电感耦合等离子体-质谱法  骨折挫伤胶囊  金属元素
DOI:10.13506/j.cnki.jpr.2020.07.004
基金项目:
Analysis of metal elements in Guzhecuoshang Capsules by ICP-MS
KONG Lingfeng1,WANG Huan2,LI Chengsen1,GUO Hanwen1,SUN Lingling1
(1.Liaoning Institute for Drug Control,Shenyang 110036,China;2.Shandong Hongrun Health Technology Co., Ltd.,Jinan 250022,China)
Abstract:
Objective To establish a method to determine the contents of Pb,Cd ,Cu,As,Hg in Guzhecuoshang Capsules by ICP-MS.Methods The sample was processed by artificial gastric juice, and 5 elements were simultaneously determined by ICP-MS method with Ge,In,Bi as internal standard elements.Results All the metal elements showed a good linear relationships(r≥0.999 0) ; The limit of detection was range from 0. 002 to 0.272 ng·mL-1,and the average recovery rate was range from 97.4% to 102.7% with a RSD less than 3.5% .Conclusion The method is simple, accurate and can be used for the quality control of Guzhecuoshang Capsules
Key words:  ICP-MS  Guzhecuoshang Capsules  Metal element
Today's Visits:488    Total Visits:2383203