• Home
  • About Journal
    Journal Introduction
    Editorial Board
    Youth Editorial Board
    Cooperating Institutions
    Editorial Department
  • Submission Guidelines
  • Policies & Statements
    Ethical Guidelines for Publication
    Academic Misconduct Statement
    Open Access (OA) Statement
    AIGC Use Statement
  • Journal Subscription
  • Download Center
  • 中文版
Cite this article:
NIU Chong,DOU Yanli,LOU Hongxiang,XU Yuwen.Improvement of determination of related substances in Mezlocillin Sodium for Injection[J].Journal Of Pharmaceutical Research,2021,40(4):229-231,261[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 2506times   Download 2536次 QR Code for this article
Scan with your phone!
注射用美洛西林钠有关物质测定方法的改进
牛冲1,窦艳丽1,娄红祥2,徐玉文1
Font:Larger+|Default|Smaller-
(1.山东省食品药品检验研究院,国家药品监督管理局仿制药研究与评价重点实验室,山东省仿制药一致性评价工程技术研究中心,山东 济南 250101;2.山东大学,山东 济南 250014)
摘要:
目的 改进注射用美洛西林钠有关物质测定方法,提高杂质的检出率。方法 采用C18色谱柱(4.6 mm×250 mm,5 μm),采用梯度洗脱,流速1.2 mL· min-1,检测波长为210 nm。结果 在上述色谱条件下,美洛西林与相邻的杂质的分离度良好,定量限为9 ng,在30.07~240.56 ng范围内线性关系良好(r=0.999 7)。杂质的个数及杂质总量较药典方法有明显提高。结论 改进后的方法简单、快速,能更好的检出注射用美洛西林钠中的杂质。
关键词:  美洛西林  杂质  有关物质  高效液相色谱
DOI:10.13506/j.cnki.jpr.2021.04.005
基金项目:山东省重点研发计划(No.2017GSF20109)
Publication Date:April 25, 2021
Improvement of determination of related substances in Mezlocillin Sodium for Injection
NIU Chong1,DOU Yanli1,LOU Hongxiang2,XU Yuwen1
(1.Shandong Institute for Food and Drug Control, Jinan 250101,China;2.NMPA Key Laboratory for Research and Evaluation of Generic Drugs;3. Shandong Research Center of Engineering and Technology for Consistency Evaluation of Generic Drugs;4.Shandong University,Jinan 250014,China)
Abstract:
Objective To improve the method for determining related substances in Mezlocillin Sodium for Injection by HPLC.Methods The determinaton was performed on a C18 column(4.6 mm×250 mm,5 μm)at the flow rate 1.2 mL · min-1 with the wavelength at 210 nm.Gradient eluent was adapted.Results An excellent separation was achieved for mezlocillin and its neighbor impurities. The LOQ was 9 ng , The linearity were found in the range of 30.07 ~ 240.56 ng (r=0.999 7). The impurities determined by this method were dramatically improved both in numbers and in contents than those measured by pharmacopeia method.Conclusion The improved method was simply and convenient,and it can determine the impurities well.
Key words:  Mezlocillin  Impurity  Related substance  HPLC
Today's Visits:487    Total Visits:2383201
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.