Cite this article:
ZHANG Naibin,CHEN Zhen,LI Chunhuan,ZHANG Xunjie,YOU Pengfei.Determination of 18 Elements in Fat Emulsion Injection and Package by ICP-MS[J].Journal Of Pharmaceutical Research,2021,40(7):441-446[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 2388times   Download 2828次 QR Code for this article
Scan with your phone!
ICP-MS检测脂肪乳注射液及包材中的18种元素
张乃斌,陈真,李春焕,张迅杰,由鹏飞
Font:Larger+|Default|Smaller-
(山东省食品药品检验研究院,仿制药研究与评价重点实验室,山东 济南 250101)
摘要:
建立电感耦合等离子体质谱法(ICP-MS)测定脂肪乳注射液及包材中的18种元素含量。确定了包材相容性中迁移元素的种类,明确了脂肪乳注射液及其包材中硼硅玻璃输液瓶和溴化丁基橡胶塞样品的前处理方法,采用标准曲线法,优化ICP-MS技术参数,检测脂肪乳注射液及包材中镉、汞、钴、铅、钒、砷、镍、锑、铝、钡、铁、锌、铈、钛、硼、硅、锂、铜共18种元素含量,并进行方法学验证。该方法操作简便、准确,精密度、准确性、稳定性、专属性好。样品充分混合硝酸后放置48 h,再经过微波消解,可充分消除脂肪乳注射液中大豆油、软磷脂等成分对元素测定的影响,可用于测定脂肪乳注射液及包材中的18种元素含量。
关键词:  脂肪乳  电感耦合等离子体质谱  包材相容性  微波消解  元素迁移  电镜扫描
DOI:10.13506/j.cnki.jpr.2021.07.005
基金项目:
Determination of 18 Elements in Fat Emulsion Injection and Package by ICP-MS
ZHANG Naibin,CHEN Zhen,LI Chunhuan,ZHANG Xunjie,YOU Pengfei
(NMPA Key Laboratory for Research and Evaluation of Generic Drugs,Shandong Institute for Food and Drug Control,Jinan 250101,China)
Abstract:
Objective An inductively coupled plasma mass spectrometry (ICP-MS) method was established for the determination of 18 elements in fat emulsion injection and package. Determine the types of migration elements in the compatibility of packaging materials. The pretreatment methods of borosilicate glass infusion bottle and brominated butyl rubber stopper in fat emulsion injection and its packaging materials were clarified. The standard curve method was used to optimize the technical parameters of ICP-MS, and 18 elements including cadmium, mercury, cobalt, lead, vanadium, arsenic, nickel, antimony, aluminum, barium, iron, zinc, cerium, titanium, boron, silicon, lithium and copper in fat emulsion injection and packaging materials were determined. The method is simple and accurate, with good precision, accuracy, stability and specificity. After the sample is mixed with nitric acid and placed for 48 h, the influence of soybean oil, soft phospholipid and other components in fat emulsion injection on the determination of elements can be eliminated. It can be used to determine 18 elements in fat emulsion injection and package.
Key words:  Fat emulsion  ICP-MS  Package compatibility  Microwave digestion  Element migration  Electron microscope Scanning
Today's Visits:483    Total Visits:2383194
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.