• Home
  • About Journal
    Journal Introduction
    Editorial Board
    Youth Editorial Board
    Cooperating Institutions
    Editorial Department
  • Submission Guidelines
  • Policies & Statements
    Ethical Guidelines for Publication
    Academic Misconduct Statement
    Open Access (OA) Statement
    AIGC Use Statement
  • Journal Subscription
  • Download Center
  • 中文版
Cite this article:
WANG Ying,YANG Mengyu,ZHAO Xia,XIAO Xinyue.Mass Extraction Method for the Closure Integrity Testing of upright polypropylene infusion bag[J].Journal Of Pharmaceutical Research,2022,41(5):299-302[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 2272times   Download 2309次 QR Code for this article
Scan with your phone!
质量提取法测试直立式聚丙烯输液袋包装的葡萄糖注射液密封完整性
王颖,杨梦雨,赵霞,肖新月
Font:Larger+|Default|Smaller-
(中国食品药品检定研究院,北京 100050)
摘要:
目的 建立质量提取法对直立式聚丙烯输液袋包装的葡萄糖注射液(规格:250 mL:12.5 g)的密封完整性进行测试。方法 进行方法参数设定及系统适用性、检出限与检测范围、耐用性、精密度等方法学验证,以及对直立式聚丙烯输液袋包装的葡萄糖注射液(规格:250 mL:12.5 g)加速0、3、6个月样品的密封完整性进行测定。结果 质量提取法方法检出限为3 μm;精密度(RSD)为2.07%~5.60%。结论 本次研究采用的质量提取法可以用于直立式聚丙烯输液袋的密封完整性测试,该方法灵敏度较高,操作简单,结果真实可靠。
关键词:  质量提取法  包装密封完整性  直立式聚丙烯输液袋
DOI:10.13506/j.cnki.jpr.2022.05.004
基金项目:
Publication Date:May 25, 2022
Mass Extraction Method for the Closure Integrity Testing of upright polypropylene infusion bag
WANG Ying,YANG Mengyu,ZHAO Xia,XIAO Xinyue
(National Institutes for Food and Drug Control, Beijing 100050, China)
Abstract:
Objective The sealing integrity of upright polypropylene infusion bag(250 mL)was tested by mass extraction method.Methods The parameters of the method was set, and the system sensitivity, detection limit and detection range, durability,and precision of the method was verified. The sealing integrity of glucose injection (250 mL: 2.25 g) packaged in upright polypropylene infusion bag was determined after 0, 3 and 6 months acceleration. Results The detection limit of the mass extraction method is 2 μm; RSD of repeatability was 2.07% - 5.60%, and RSD of intermediate precision was 6.03%~7.83%.Conclusion The mass extraction method used in this study can be used to test the sealing integrity of upright polypropylene infusion bag. This method has high sensitivity,simple operation and reliable results.
Key words:  Mass extraction method  Closure integrity testing  Upright polypropylene infusion bag
Today's Visits:492    Total Visits:2383211
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.