• Home
  • About Journal
    Journal Introduction
    Editorial Board
    Youth Editorial Board
    Cooperating Institutions
    Editorial Department
  • Submission Guidelines
  • Policies & Statements
    Ethical Guidelines for Publication
    Academic Misconduct Statement
    Open Access (OA) Statement
    AIGC Use Statement
  • Journal Subscription
  • Download Center
  • 中文版
Cite this article:
XU Xiaoqian,ZHOU Jiatong,WEN Songsong,WANG Xue,NIU Chong,GUO Changchuan,ZHANG Lianyi,XU Yuwen,XIANG Yu.Determination of polyoxyl(40) hydrogenated castor oil in lidocaine-prilocaine cream using high performance liquid chromatography coupled with charged aerosol detector[J].Journal Of Pharmaceutical Research,2025,44(7):669-673[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 2040times   Download 789次 QR Code for this article
Scan with your phone!
高效液相色谱联用电喷雾检测器解析利丙双卡因乳膏中聚氧乙烯(40)氢化蓖麻油的含量
徐晓茜1,周佳彤2,文松松3,王雪3,牛冲3,郭常川3,张连义3,徐玉文3,向宇3
Font:Larger+|Default|Smaller-
(1.北京师范大学化学学院,北京 100875;2.华东师范大学生命科学学院,上海 200062;3.山东省食品药品检验研究院,国家药品监督管理局仿制药研究与评价重点实验室,山东省仿制药一致性评价工程技术研究中心,产业技术基础公共服务平台,山东 济南 250101)
摘要:
目的 建立了测定利丙双卡因乳膏中聚氧乙烯(40)氢化蓖麻油含量的高效液相色谱联用电喷雾检测器分析方法(HPLC-CAD)。方法 样品以无水乙醇为溶剂加热提取。样品溶液采用Acclaim Surfactant Plus色谱柱(4.6 mm× 150 mm,5 μm)分离,流动相为0.1%(v/v)七氟丁酸水溶液-异丙醇,梯度洗脱。采用电喷雾检测器,雾化器温度为50 ℃,采样频率为10 Hz,过滤常数为3.6 s,标准曲线法定量。结果 方法专属性良好,溶剂及其他组分对测定无干扰;聚氧乙烯(40)氢化蓖麻油在2.34~250 μg·mL-1范围内线性关系良好,相关系数(r)≥0.999 8;聚氧乙烯(40)氢化蓖麻油在低、中、高3个水平下的回收率为96.8%~101.6%,RSD为1.2%~2.3%;精密度、稳定性试验的RSD(n=6)均小于2%。采用建立的方法对6批仿制制剂进行测定,聚氧乙烯(40)氢化蓖麻油含量与原研制剂基本一致。结论 该方法简便、快速、灵敏、准确,为利丙双卡因乳膏的处方解析提供了技术支持,同时填补了聚氧乙烯(40)氢化蓖麻油定量分析的技术空白,为药用辅料质量标准提高奠定了基础。
关键词:  高效液相色谱  电喷雾检测器  聚氧乙烯(40)氢化蓖麻油  利丙双卡因乳膏
DOI:10.13506/j.cnki.jpr.2025.07.007
基金项目:国家自然科学基金项目(No.81573606、81973486);泰山产业领军人才工程专项经费项目(No.tscx202306073)
Determination of polyoxyl(40) hydrogenated castor oil in lidocaine-prilocaine cream using high performance liquid chromatography coupled with charged aerosol detector
XU Xiaoqian1,ZHOU Jiatong2,WEN Songsong3,WANG Xue3,NIU Chong3,GUO Changchuan3,ZHANG Lianyi3,XU Yuwen3,XIANG Yu3
(1.Beijing Normal University,Beijing ;2. East China Normal University, Shanghai, 200062;3.NMPA Key Laboratory for Research and Evaluation of Generic Drugs, Shandong Research Center of Engineering and Technology for Consistency Evaluation of Generic Drugs, Industrial Technology Foundation Public Service Platform, Shandong Institute for Food and Drug Control, Jinan, 250101, China; 4. Key Laboratory of Chemical Biology, Ministry of Education, Shandong University, Jinan 250101, China)
Abstract:
Objective A high-performance liquid chromatography coupled with charged aerosol detector (HPLC-CAD) method was established for the determination of polyoxyl(40) hydrogenated castor oil in lidocaine-prilocaine cream. Methods The sample was heated and extracted with anhydrous ethanol. The chromatographic column was Acclaim Surfactant Plus (4.6 × 150 mm, 5 μm) column, the mobile phase was 0.1% (v/v) heptafluorobutyric acid-isopropanol (gradient elution). The parameters of CAD were as follows: atomization temperature was 50 ℃, sampling frequency was 10 Hz, and the filtration constant was 3.6 s. Quantification was conducted using the standard curve method. Results The method specificity was good. Solvent and other components did not interfere with the determination. Polyoxyl(40) hydrogenated castor oil showed a good linearity (r>0.9995) in the concentration range of 25~250 μg·mL-1. The recovery rate was in the range of 96.8%~101.6% at low, medium, and high concentrations, and the relative standard deviation (RSD) was 1.2%~2.3%. The RSDs of precision and stability were all less than 2%. We detected six batches of generic preparations using the established method. The results showed that the content of polyoxyl(40) hydrogenated castor oil was consistent with that of original preparations. Conclusion This method is simple, rapid, sensitive, and accurate, which provides technical support for the prescription analysis of lidocaine-prilocaine cream, fills the technical gap in the quantitative analysis of polyoxyl(40) hydrogenated castor oil, and lays a foundation for the enhancement of the quality standard of pharmaceutical excipients.
Key words:  High-performance liquid chromatography (HPLC)  Charged aerosol detector (CAD)  Polyoxyl(40) hydrogenated castor oil  Lidocaine-prilocaine cream
Today's Visits:509    Total Visits:2383239
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.