Cite this article:
LIU Huixiang,LIU Wentao,GAO Tianyang,WANG Xingxing,KONG Xiangyu,SONG Wenyan,WANG Yan,XIE Qiangsheng.Determination of vitamin D3 content in vitamin D drops by an internal standard method based on on line solid phase extraction two-dimensional liquid chromatography[J].Journal Of Pharmaceutical Research,2026,45(9):1007-1012[Click to copy]
【Print this page】      【Download PDF Full Text】   【View/Add Comment】  【Download reader】  【 Close 】
←Previous|Next→ Archive    Advanced Search
This article has been viewed: 229times   Download 195次 QR Code for this article
Scan with your phone!
基于在线固相萃取二维液相色谱的内标法测定维生素D滴剂中维生素D3含量
刘慧香1,刘文涛2,高天阳1,王星星3,孔祥雨2,宋文艳3,王燕1,谢强胜1
Font:Larger+|Default|Smaller-
(1.山东省食品药品检验研究院,工业和信息化部产业技术基础公共服务平台,国家药品监督管理局监管科学创新研究基地,山东省仿制药一致性评价工程技术研究中心,山东 济南 250101;2.山东省药学科学院,山东 济南 250101;3.华夏国药<菏泽>制药有限公司,山东 菏泽 274000)
摘要:
目的 建立基于在线固相萃取二维液相色谱测定维生素D滴剂中维生素D3含量的内标方法。方法 以维生素D2为内标,样品经皂化处理后定容,采用在线固相萃取-二维液相色谱联用进行检测;在线固相萃取采用Agilent PLRP-S(4.6 mm×12.5 mm,15 μm)固相萃取柱,以水-乙腈-甲醇-甲基叔丁基醚作为淋洗液;第一维液相色谱采用Agilent Poroshell 120 PFP(4.6 mm×100 mm,4 μm)色谱柱,以0.1%磷酸-甲醇为流动相进行梯度洗脱;第二维液相色谱采用ShimNex S-C18-PAH(4.6 mm×150 mm,3 μm)色谱柱,以甲醇为流动相进行等度洗脱;检测波长为264 nm;配备两个多中心切割阀,在不同时间节点进行切割,对维生素D2和维生素D3峰进行多次切割,达到有效分离和测定。结果 维生素D3在0.557 5~55.75 μg•L-1范围内,线性关系良好(r≥0.999 9);维生素D3仪器精密度和中间精密度试验RSD分别是1.0%和0.89%;重复性试验RSD为0.62%;平均加标回收率为100.5%;供试品溶液在24 h内稳定性试验RSD为0.86%;维生素D3检出限和定量限分别为0.17 和0.56 μg•L-1;6批样品中维生素D3含量为标示量的99.1%~102.3%。结论 本研究建立在线固相萃取-二维液相色谱内标法对维生素D滴剂中维生素D3含量进行测定,可以实现目标组分与辅料的完全分离和目标物的准确定量,该技术可为难分离样品的定量分析提供参考。
关键词:  在线固相萃取  二维液相  维生素D3  内标法  维生素D滴剂
DOI:10.13506/j.cnki.jpr.2026.09.007
基金项目:
Received Date:June 16, 2026   Revision Date:September 15, 2026   Publication Date:September 30, 2026
Determination of vitamin D3 content in vitamin D drops by an internal standard method based on on line solid phase extraction two-dimensional liquid chromatography
LIU Huixiang1,LIU Wentao2,GAO Tianyang1,WANG Xingxing3,KONG Xiangyu2,SONG Wenyan3,WANG Yan1,XIE Qiangsheng1
(1.Ministry of Industry and Information Technology Industrial Technology infrastructure Public Service Platform,NMPA Regulatory Science Innovation Research Base,Shandong Engineering and Technology Research Center for Generic Drug Consistency Evaluation,Shandong Institute for Food and Drug Control,Jinan 250101,China;2.Shandong Academy of Pharmaceutical Sciences,Jinan 250101,China;3.Cathay Biopharmaceutical Co., Ltd.,Heze 274000,China)
Abstract:
Objective To establish an internal standard method for the determination of vitamin D3 in vitamin D drops based on on-line solid-phase extraction two-dimensional liquid chromatography. Methods Vitamin D2 was used as the internal standard. After saponification and dilution, the sample was detected by on-line solid-phase extraction coupled with two-dimensional liquid chromatography. On-line solid-phase extraction was performed on an Agilent PLRP-S (4.6 mm×12.5 mm, 15 μm) column using water-acetonitrile-methanol-methyl tert-butyl ether as the washing solvent. The first-dimensional liquid chromatography was performed on an Agilent Poroshell 120 PFP (4.6 mm×100 mm, 4 μm) column with a gradient elution using 0.1% phosphoric acid-methanol as the mobile phase. The second-dimensional liquid chromatography was performed on a ShimNex S-C18-PAH (4.6 mm×150 mm, 3 μm) column with isocratic elution using methanol as the mobile phase. The detection wavelength was 264 nm. Equipped with two multi-center cutting valves, multiple cuts of vitamin D2 and vitamin D3 peaks were performed at different time points to achieve effective separation and determination. Results Vitamin D3 showed a good linear relationship in the range from 0.557 5 to 55.75 μg·L-1(r≥0.999 9). The RSD for instrument precision and intermediate precision of vitamin D3 were 1.0% and 0.89%, respectively. The RSD for repeatability was 0.62%. The average spiked recovery was 100.5%. The RSD for solution stability test within 24 hours was 0.86%. The limit of detection (LOD) and limit of quantification (LOQ) for vitamin D3 were 0.17 and 0.56 μg·L-1, respectively. The vitamin D3 content in six batches of samples ranged from 99.1% to 102.3% of the labeled amount. Conclusion The on-line solid-phase extraction two-dimensional liquid chromatography internal standard method established in this study can achieve complete separation and accurate quantification of the target component. This technique provides a reference for the quantitative analysis of difficult-to-separate samples.
Key words:  On-line solid-phase extraction  Two-dimensional liquid chromatography  Vitamin D3  Internal standard method  Vitamin D drops
Today's Visits:511    Total Visits:2383242
Website copyright:Editorial Board of Journal of Pharmaceutical Research     鲁ICP备17018036号-3     鲁公网安备 37010202001351号
Sponsored by:Shandong Institute for Food and Drug Control Shandong Pharmaceutical Association Address:No.2749 Xinluo Street,High-Tech Zone,Jinan,P.R.China Postcode:250101
Telephone Number:0531-81216586 Email :yaoxueyanjiu@163.com;yaoxueyanjiu@126.com
Technical Support:Beijing Qinyun Technology Co., Ltd.